Product Overview and Selection Scope
NB5R5C105N-HT is a 5.0 V rated, 5.5 V surge, 1.0 F C-type coin supercapacitor with same-side solder tabs. Its compact package is intended for RTC backup, low-power state retention and short data-save intervals where PCB area is limited.
This device is polarized and its terminal voltage falls during discharge. Verify the ESR step, capacitance tolerance, load profile, leakage, charging current and minimum system voltage in the complete circuit.
Part-Number Construction
The designation is decoded below using the naming table in the supplied specification.
| Segment | Meaning | Value for this product | Engineering note |
|---|---|---|---|
| NB | Series | Coin supercapacitor | Identifies the source NB button-type product family. |
| 5R5 | Series voltage code | 5.5 V surge | The continuous rated operating voltage is 5.0 V. |
| C | Terminal format | C-type same-side solder tabs | Confirm the footprint and marked polarity before PCB release. |
| 105 | Capacitance code | 1.0 F | Nominal capacitance before tolerance, temperature and ageing margins. |
| N | Capacitance tolerance | −20% to +80% | Use 0.8 F as the initial minimum for conservative calculations. |
| HT | Temperature version | High-temperature type | Specified operating range: −40 °C to +85 °C. |
Electrical Characteristics
Values below are transcribed from the supplied NYFEA specification. Rated operating voltage and surge voltage are separate limits.
| Parameter | Condition | Specified value | Unit |
|---|---|---|---|
| Rated operating voltage | UR | 5.0 | V |
| Surge voltage | Maximum source-specified surge | 5.5 | V |
| Nominal capacitance | C | 1.0 | F |
| General capacitance tolerance | IEC 62391-1 | −20 to +80 | % |
| Controlled capacitance tolerance | Controlled option | −10 to +20 | % |
| Category temperature range | Ambient | −40 to +85 | °C |
| Maximum ESR | 1 kHz, 10 mA, room temperature | 15 | Ω |
| Leakage current | After 24 h at rated voltage | 10 | µA |
| Rated operating current | Source value | 10 | mA |
| Instantaneous maximum working current | Source value | 60 | mA |
Mechanical Dimensions and Polarity
The component uses a polarized C-type coin construction with both solder tabs extending from the same side. Confirm PCB polarity before assembly.
| Dimension | Nominal | Tolerance | Design use |
|---|---|---|---|
| Body diameter | 21.0 mm | ±0.5 mm | Cylindrical envelope |
| Body thickness | 10.5 mm | ±0.5 mm | Axial package depth |
| Terminal spacing | 5.0 mm | ±0.5 mm | PCB hole spacing |
| Lead projection | 5.0 mm | ±1.0 mm | Minimum layout allowance |
| Terminal features B / C / E | 0.5 / 0.8 / 1.2 mm | Per controlled drawing | Verify the released PCB footprint against the source drawing. |
Reliability and Endurance
| Test | Source condition | Capacitance requirement | ESR requirement |
|---|---|---|---|
| Load life | 5.0 V at +85 ±2 °C for 1000 h | Decrease ≤30% from initial | ≤4 × specified value |
| Temperature characteristics | +85 ±2 °C / −25 ±2 °C source test points | Within ±30% at +85 °C; ≥50% of initial at −25 °C | ≤ specified value at +85 °C; ≤4 × specified value at −25 °C |
| Storage life | +85 ±2 °C for 1000 h after charging to rated voltage | Within ±30% of initial | ≤2 × specified value |
| Damp heat | +85 °C / 85% RH for 240 h after 1 h at rated voltage | Within ±30% of initial | ≤4 × specified value |
Capacitance and ESR Test Methods
For capacitance measurement, charge the device to rated voltage for 30 minutes and discharge it at the prescribed constant current. ESR is measured using the specified 1 kHz AC method.
Hold-Up, Leakage and Energy Calculations
Estimate the usable interval from the allowable voltage window and load current, then subtract the immediate ESR voltage step. For leakage-current verification, apply the 5.0 V rated operating voltage and measure the current after the source-specified 24-hour charging period.
PCB Mounting, Soldering and Handling
Assembly and environmental conditions directly affect reliability. Apply the following source-specification precautions during layout and process qualification.
If devices are connected in series, implement voltage balancing and obtain NYFEA application guidance. Also validate hole size, lead pitch, cleaning chemistry, polarity inspection and mechanical support before release.
Application Guidance and Design Limitations
The applications below are engineering use cases consistent with a compact 5.0 V rated, 1.0 F backup component. They are not end-product certification claims.
The source specification does not claim automotive, medical, functional-safety, life-support or fault-tolerant qualification. Confirm all mandatory standards for the end product.
NB5R5C105N-HT Engineering FAQs
What are the rated voltage and nominal capacitance?
The rated operating voltage is 5.0 V, the surge voltage is 5.5 V, and the nominal capacitance is 1.0 F.
What capacitance tolerance is specified?
The supplied specification states −20% to +80%, corresponding to an initial range of 0.8 F to 1.8 F before additional temperature and ageing allowances.
What is the maximum ESR?
The maximum ESR is 15 Ω at 1 kHz and 10 mA at room temperature.
What is the operating temperature range?
The specified operating range is −40 °C to +85 °C.
What are the package dimensions and lead pitch?
The nominal body is Ø21.0 × 10.5 mm, with a 5.0 mm nominal terminal spacing and flat tab terminals.
Is the component polarized?
Yes. Match the negative marking to the PCB polarity before soldering.
Can it be used as a direct battery replacement?
No. A supercapacitor has continuous voltage decay and an ESR-related voltage step. Validate the load current, minimum system voltage, usable energy and required hold-up time.
What is the difference between rated and surge voltage?
Use 5.0 V as the continuous rated operating voltage. The 5.5 V value is the source-specified surge voltage, not the continuous rating.
Which document controls production decisions?
The supplied NB5R5C105N-HT PDF and the current NYFEA-controlled revision remain the design authority.
This page summarizes the supplied NB5R5C105N-HT product specification for component evaluation. Confirm the current revision, dimensions, polarity, rated-versus-surge voltage, test conditions, assembly process and qualification requirements before production release.